Bought an air conditioner and the room is still hot? It may be the sizing
Summer arrives, the new unit is installed, and the bedroom still does not cool down. Turning the number down on the remote does not fix a lack of cooling capacity. It is worth checking whether the BTU calculation considered more than floor area.
Why 20 m² is not an answer
BTU/h measures how much heat the unit can remove per hour under test conditions. How much heat has to be removed depends on more than area: sun through the windows, especially in the afternoon, heated walls and roof, gaps around doors and windows, number of people, equipment turned on and thermal insulation. So two 20 m² rooms can need different capacities.
The tables that circulate are references, not rules. A Brazilian federal public-procurement catalog (SENASP, 2021), for example, suggests 12,000 BTU/h for 16 to 20 m² with morning sun and 15,000 BTU/h with afternoon or all-day sun, but it assumes one person, one window and one computer.
What inverter does not do
An inverter adjusts the compressor speed and can use less energy in some conditions. It does not exceed the unit's nominal capacity. If the room's thermal load is higher, the imbalance remains.
Not just a home problem
A study in the journal Vértices (2017) compared the units in the classrooms of an educational institution with the thermal load calculated under ABNT NBR 5858:1983 and NBR 16401-1:2008. Result: none of the rooms had a unit suited to the calculated load, and in 7 of them NBR 16401-1 gave a higher load. It was a specific case, but it shows that calculating the load before choosing a unit pays off.
Before blaming the unit
Clogged filters, poor air circulation, improper installation and refrigerant circuit problems also hurt performance. A qualified technician can find the cause.
How to choose well
- Ask for a thermal load calculation, not just “how many m² the room has”. In projects, the reference is NBR 16401-1.
- Tell the professional about window orientation, afternoon sun, how many people use the room and which equipment stays on.
- Compare models using the Inmetro Brazilian Labeling Program table, which gathers capacity, power, classification and consumption.
- After installation, check filters, installation and the refrigerant circuit before concluding the unit is too weak.